Taking the BX series as an example:

1. First, ensure the control card and screen are properly connected. After powering on, observe whether the screen displays normally (default 1/16 scan display is normal).

2. Communication hardware check: For the 232 serial port, pins 2, 3, and 5 are straight-through; for the 485 serial port, pins 7 (positive), 8 (negative), and 5 (ground) are straight-through (a 232-485 converter is required for the computer's serial port). For a baud rate of 9600: white DIP switches B0 and B1 are on the digital side; for a baud rate of 57600: B1 is on the ON side, and B0 is on the digital side (other DIP switches P0-P7 are screen number dials, all on the digital side, defaulting to screen number 1; binary dialing adds screens). The jumper caps on the control card can adjust 232/485 communication; horizontal jumping is sufficient. (Power off and adjust before powering on for communication).

3. Software settings: Open the software, click 'Settings' - 'Set Screen' - 'Password: 168'; in hardware settings, select the control group 'BX-?' 1. Select the communication COM port and the control card baud rate (corresponding to the one on the control card); 2. Software settings: parameters corresponding to the unit board data. (For control cards with verification, the software verification settings window needs to be opened during serial communication. Press the ALT key and the - key simultaneously, and in the pop-up window, enable verification, click OK, and then restart the software for communication.)

4. Display settings: If the connection between the control card and the screen is abnormal, first check the hardware connection, such as whether the ribbon cable is inserted backwards or whether the interface definition matches the signal. Then check whether the scanning method corresponding to the data flow of the module driver chip is loaded and set correctly. If the screen display is abnormal under normal communication conditions, set the scanning method, and then select the data flow corresponding to the screen in the scan settings. After successful loading (if the display is normal, there is no need to download BX-A/BX-T), download the capacitor (BX-E). For the BX-C2/M2 card, the scanning method is under the "Scan Settings" menu in the 3.0 software settings, enter with the password three 8s, select the module unit board data flow, and click Set Scan Method.

5. If a black screen and data loss occur, turn off all white DIP switches on the control card and switch them to the ON side (the other side of the digital display). After powering on, observe the screen changes (default 1/16 scan). If it displays (Screen parameter number: 0), reset the white DIP switches and reload/send.