How to Perform Loop Testing on an LED Switching Power Supply Using an Oscilloscope?

Mar 24, 2026

Leave a message

 

Oscilloscope Method for Loop Testing on an LED Switching Power Supply:

The oscilloscope plays a crucial role in loop testing of LED switching power supplies, primarily used to measure and analyze the stability of the power supply control loop. The following are the specific steps and methods for performing loop testing using an oscilloscope:

I. Test Preparation

Equipment Selection:

Oscilloscope: Select an oscilloscope with sufficient bandwidth and accuracy, such as the Siglent SDS6104 H12 Pro, to ensure accurate capture and analysis of high-frequency signals.

Signal Generator: Such as the Siglent SAG1021I, used to provide the injection signal required for the test.

Other Auxiliary Equipment: Including probes, injection resistors, injection transformers, etc.

Test Environment Setup:

Ensure the test environment is free from interference to avoid affecting the test results.

Connect the LED switching power supply under test to the test system and correctly connect the oscilloscope, signal generator, and other equipment.

II. Disconnecting the Loop and Injecting a Signal

Disconnecting the Loop:

Choose a suitable point in the feedback system to disconnect the loop, typically between the output and feedback networks.

Note that when disconnecting the loop, maintain the circuit's quiescent operating point to avoid output saturation.

Loop Injection:

Insert a very small injection resistor (e.g., 4.99Ω) at the disconnect point and inject a test signal through it.

The injected signal should be small enough to avoid affecting the loop's quiescent operating point.

An injection transformer can be used to reduce grounding issues between the signal source and the device under test (DUT).

III. Setting Up the Oscilloscope and Signal Source

Oscilloscope Settings:

Set the oscilloscope channels to an appropriate bandwidth limit, such as 20MHz.

Configure the Bode Plot software, setting the DUT inputs and outputs to the corresponding channels.

Set the scan type, scan parameters, frequency mode, etc., to ensure accurate measurement of the loop's gain and phase.

Signal Source Settings:

Set the signal source's output amplitude and frequency to suit the characteristics of the DUT.

Ensure the connection between the signal source and the oscilloscope is correct.

IV. Performing Tests

Running the Scan:

Start the scan in Bode Plot software and record the gain and phase curves of the loop as a function of frequency.

Observe the gain and phase curves and analyze the loop stability.

Data Analysis:

Calculate gain margin and phase margin based on the gain and phase curves.

Evaluate the loop stability and adjust and optimize as needed.

V. Precautions

Test Signal Selection:

The amplitude and frequency of the test signal should be moderate to avoid excessive influence on the loop.

Select an appropriate test signal based on the characteristics of the loop under test.

Test Point Selection:

The selection of test points should be reasonable to ensure accurate reflection of the loop characteristics.

Select appropriate test points based on the circuit design and testing requirements.

Test Result Verification:

Verify and analyze the test results to ensure their accuracy and reliability.

Other test methods or equipment can be used for verification and comparison.

Send Inquiry